ReadonlyisWhether eco hot-water mode is on; null where the wire cannot say
(Home).
ReadonlyisWhether forced hot-water production is on.
ReadonlyisWhether hot-water production is currently inhibited.
ReadonlylastInstant of the last legionella-prevention cycle, in epoch
milliseconds; null where the wire cannot say — Home has no
counterpart in its /context settings, and Classic reads null
when no cycle was ever recorded (the year-1 sentinel) or the wire
value cannot be parsed. The Classic stamp is BUILDING-local wall
clock anchored in the client's configured timezone
(ClassicAPIConfig.timezone, the host's zone when unset): exact
only insofar as that timezone is the building's — a building in
another zone skews the instant by the zone delta, so day-scale
reasoning stays safe where sub-hour reasoning does not.
ReadonlymaxReported tank maximum, in °C; null where the wire cannot say
(Home only advertises the setpoint clamp bound, a different thing).
ReadonlyoperationalDerived hot-water operational state, same precedence on both
dialects: forced reads dhw, prohibited reads prohibited, else
the operation mode decides between dhw, legionella and idle.
ReadonlysetTank-water setpoint, in °C.
ReadonlytankLast-reported tank-water temperature, in °C.
Hot-water snapshot of an ATW unit in the cross-dialect vocabulary.